Hand Held Pneumatic Pump
Type:
Pneumatic Calibration Pump
Pressure Range:
-0.095 ~6.0MPa
Medium:
Clean Air
Operating Temperature:
0- 50℃
Highlight:

60Bar Pneumatic Calibration Pump

,

Hand Held Pneumatic Calibration Pump

,

Clean Air Pressure Pump

Product Description

60 Bar Hand-Held Pneumatic Calibration Pump Clean Air Pressure Pump

Hand pump pressure transmitter calibrator is a portable pressure pump. This pressure transmitter calibrator is for field installation of instrument calibration in the industrial process and control of indoor use all kinds of pressure gauges.This hand pump pressure calibrator also provide pressure source correction table for pressure measuring instrument manufacturer. The handheld pressure calibrator for all kinds of pressure transmitter within every 60 Mpa,Pressure sensor and all kinds of pressure gauges Check all available hand pressure pump calibrator

 

Specification

item

value

Type

Pressure pump

Warranty

1 Year

Customized support

OEM, OBM, ODM

Brand Name

XINYI

Model Number

YFP-60

Product name

Hand held pneumatic pump

Pressure range

-0.095 ~6.0MPa

Medium

clean air

Type

pneumatic

 

Operation method

Pressure verification First, connect the tested meter to the output of the tested meter, and connect the standard meter to the output of the standard meter. Rotate the switch valve knob to push it out, and turn the pressure adjustment knob counterclockwise to close the pressure relief valve. Use the pressure handle to apply pressure to around 0.5-4MPa, and use the pressure adjustment knob to apply pressure to the desired level. When releasing pressure, simply open the pressure relief valve.

Vacuum calibration First, connect the tested meter to the output of the tested meter, and connect the standard meter to the output of the standard meter. Rotate the switch valve knob and press it in, then turn the pressure adjustment knob clockwise to close the pressure relief valve. Use the pressure handle to draw pressure to the desired vacuum value. When releasing pressure, simply open it.

 

Note

1. The device should be used within the rated pressure range as much as possible and should not be used beyond the range.

2. The pressure/vacuum conversion must be carried out in a non pressure state.

3. The calibration table should be placed on a stable operating platform to avoid entering environments with corrosive gases and dust particles.

4. If not used for a long time, the equipment should be stored in a dry, non corrosive gas environment;

5. Leverage pressure, apply even force, do not use force when closing or opening the valve.

6. Regularly clean the impurities inside the filter to prevent them from affecting the service life of the equipment.

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 0

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 1

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 2

 

products
PRODUCTS DETAILS
60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump
MOQ: 1PC
Standard Packaging: Carton
Delivery Period: 5-8 work days
Payment Method: L/C,D/P,D/A,T/T,Western Union
Supply Capacity: 100pcs/month
Detail Information
Place of Origin
China
Brand Name
XINYIYB
Model Number
YFP-60
Product Name:
Hand Held Pneumatic Pump
Type:
Pneumatic Calibration Pump
Pressure Range:
-0.095 ~6.0MPa
Medium:
Clean Air
Operating Temperature:
0- 50℃
Minimum Order Quantity:
1PC
Packaging Details:
Carton
Delivery Time:
5-8 work days
Payment Terms:
L/C,D/P,D/A,T/T,Western Union
Supply Ability:
100pcs/month
Highlight

60Bar Pneumatic Calibration Pump

,

Hand Held Pneumatic Calibration Pump

,

Clean Air Pressure Pump

Product Description

60 Bar Hand-Held Pneumatic Calibration Pump Clean Air Pressure Pump

Hand pump pressure transmitter calibrator is a portable pressure pump. This pressure transmitter calibrator is for field installation of instrument calibration in the industrial process and control of indoor use all kinds of pressure gauges.This hand pump pressure calibrator also provide pressure source correction table for pressure measuring instrument manufacturer. The handheld pressure calibrator for all kinds of pressure transmitter within every 60 Mpa,Pressure sensor and all kinds of pressure gauges Check all available hand pressure pump calibrator

 

Specification

item

value

Type

Pressure pump

Warranty

1 Year

Customized support

OEM, OBM, ODM

Brand Name

XINYI

Model Number

YFP-60

Product name

Hand held pneumatic pump

Pressure range

-0.095 ~6.0MPa

Medium

clean air

Type

pneumatic

 

Operation method

Pressure verification First, connect the tested meter to the output of the tested meter, and connect the standard meter to the output of the standard meter. Rotate the switch valve knob to push it out, and turn the pressure adjustment knob counterclockwise to close the pressure relief valve. Use the pressure handle to apply pressure to around 0.5-4MPa, and use the pressure adjustment knob to apply pressure to the desired level. When releasing pressure, simply open the pressure relief valve.

Vacuum calibration First, connect the tested meter to the output of the tested meter, and connect the standard meter to the output of the standard meter. Rotate the switch valve knob and press it in, then turn the pressure adjustment knob clockwise to close the pressure relief valve. Use the pressure handle to draw pressure to the desired vacuum value. When releasing pressure, simply open it.

 

Note

1. The device should be used within the rated pressure range as much as possible and should not be used beyond the range.

2. The pressure/vacuum conversion must be carried out in a non pressure state.

3. The calibration table should be placed on a stable operating platform to avoid entering environments with corrosive gases and dust particles.

4. If not used for a long time, the equipment should be stored in a dry, non corrosive gas environment;

5. Leverage pressure, apply even force, do not use force when closing or opening the valve.

6. Regularly clean the impurities inside the filter to prevent them from affecting the service life of the equipment.

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 0

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 1

60Bar Hand Held Pneumatic Calibration Pump Clean Air Pressure Pump 2

 

Sitemap |  Privacy Policy | China Good Quality Differential Pressure Transmitter Supplier. Copyright © 2025 Xi'an Xinyi Instrument Technology Co., Ltd. . All Rights Reserved.