| MOQ: | 1pcs |
| Price: | CN¥2,914.54-5,105.92/sets |
| Standard Packaging: | Carton |
| Delivery Period: | 3-4weeks |
| Payment Method: | L/C,T/T,Western Union,D/P,D/A |
| Supply Capacity: | 1,000 per month |
| Output | Analog output: two-wire 4-20mA DC Digital output: two-wire 4-20mA DC with superimposed HART protocol variable digital signal |
|---|---|
| Power Supply | 12.5-45V DC |
| Limit Load | Maximum load resistor determined by supply voltage. HART protocol requires load resistor between 250Ω and 600Ω |
| Communication Distance | Maximum 1.5Km, supports multi-address communication for up to 15 smart transmitters |
| Display | 4 digital display, 5 digit LCD display, pointer type |
| Explosion-proof | ExiaIICT5; explosion suppression type |
| Zero Offset | Supports positive or negative transfer within maximum limits |
| Temperature Range | Ambient: -40°C to 85°C (-20°C to 70°C with LCD) Medium: -40°C to 104°C |
| Static Pressure & Overpressure | 3.45KPa (absolute pressure) to 31.2MPa (gauge pressure) |
| Relative Humidity | 5-98% RH |
| Start-up Time | Less than 5 seconds |
| Capability Change | Less than 0.16cm³ |
| Damping Adjustment | 0.20 to 25 seconds |
| Fault Alarm | Automatic diagnosis outputs 3.9 or 21.0mA upon malfunction detection |
| Configuration Protection | Software or protection switch locking to prevent unauthorized data modification |